An effective molecule titration for the ninth component of complement in the biologic fluids of man was developed using EAC1-8 cells produced by treating EAC14 cells with a chromatographic fraction of human serum containing C2, C3, C5, C6, C7, and C8. Kinetic studies of the interaction of EAC1-8 with C9 indicated that this component was depleted from the fluid phase, and that the lytic reaction proceeded most rapidly at ionic strength 0.145, and at a temperature of 37°C. The mean value for C9 in normal serum was 52,000 ±12,000 units/ml. The mean serum C9 for patients with DJD, rheumatoid arthritis, or SLE without active renal disease was approximately twice the mean for normal individuals. Patients with SLE and active renal disease had a mean C9 value which fell within the normal range, but was significantly lower than in patients with SLE who did not have active renal disease. Two instances of absolutely subnormal C9 levels were observed in patients during attacks of florid SLE, including nephritis. Since the usual change in serum C9 in rheumatic diseases is a marked elevation, the occurrence of a subnormal value reflects circumstances in which depletion due to activation of the sequence exceeds the increases associated with the inflammatory response.
Skip Nav Destination
Article navigation
1 September 1971
Article|
September 01 1971
HEMOLYTIC ASSAY OF THE NINTH COMPLEMENT COMPONENT: ELEVATION AND DEPLETION IN RHEUMATIC DISEASES
Shaun Ruddy,
Shaun Ruddy
From the Harvard Medical School, Robert B. Brigham Hospital, Boston, Massachusetts 02120
Search for other works by this author on:
Lloyd K. Everson,
Lloyd K. Everson
From the Harvard Medical School, Robert B. Brigham Hospital, Boston, Massachusetts 02120
Search for other works by this author on:
Peter H. Schur,
Peter H. Schur
From the Harvard Medical School, Robert B. Brigham Hospital, Boston, Massachusetts 02120
Search for other works by this author on:
K. Frank Austen
K. Frank Austen
From the Harvard Medical School, Robert B. Brigham Hospital, Boston, Massachusetts 02120
Search for other works by this author on:
Shaun Ruddy
From the Harvard Medical School, Robert B. Brigham Hospital, Boston, Massachusetts 02120
Lloyd K. Everson
From the Harvard Medical School, Robert B. Brigham Hospital, Boston, Massachusetts 02120
Peter H. Schur
From the Harvard Medical School, Robert B. Brigham Hospital, Boston, Massachusetts 02120
K. Frank Austen
From the Harvard Medical School, Robert B. Brigham Hospital, Boston, Massachusetts 02120
Online ISSN: 1540-9538
Print ISSN: 0022-1007
Copyright © 1971 by The Rockefeller University Press
1971
J Exp Med (1971) 134 (3): 259–275.
Citation
Shaun Ruddy, Lloyd K. Everson, Peter H. Schur, K. Frank Austen; HEMOLYTIC ASSAY OF THE NINTH COMPLEMENT COMPONENT: ELEVATION AND DEPLETION IN RHEUMATIC DISEASES . J Exp Med 1 September 1971; 134 (3): 259–275. doi: https://doi.org/10.1084/jem.134.3.259
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.
Sign in via your Institution
Sign in via your InstitutionEmail alerts
Advertisement