The equivalent circuit that has been used in the analysis of nerve voltage-clamp data is that of the membrane capacity in parallel with the membrane resistance. Voltage-clamp experiments on frog atrial tissue indicate that this circuit will not suffice for this cardiac tissue. The change in membrane current associated with a step change in membrane potential does not show a rapid spike of capacitive current as would be expected for the simple parallel resistance-capacitance network. Rather, there is a step change in current followed by an exponential decay in current with a time constant of about 1 msec. This relatively slow capacitive charging current suggests that there is a resistance in series with the membrane capacity. A possible equivalent circuit is that of a series resistance external to the parallel resistance-capacitance network of the cell membranes. Another possible circuit assumes that the series resistance is an integral part of the cell membrane. The data presented in this paper demonstrate that the equivalent circuit of a bundle of frog atrial muscle is that of an external resistance in series with the cell membranes.
Skip Nav Destination
Article navigation
1 November 1971
Article|
November 01 1971
Equivalent Circuit of Frog Atrial Tissue as Determined by Voltage Clamp-Unclamp Experiments
Merrill Tarr,
Merrill Tarr
From the Department of Physiology, University of Kansas Medical Center, Kansas City, Kansas 66103
Search for other works by this author on:
John Trank
John Trank
From the Department of Physiology, University of Kansas Medical Center, Kansas City, Kansas 66103
Search for other works by this author on:
Merrill Tarr
From the Department of Physiology, University of Kansas Medical Center, Kansas City, Kansas 66103
John Trank
From the Department of Physiology, University of Kansas Medical Center, Kansas City, Kansas 66103
Received:
February 17 1971
Online ISSN: 1540-7748
Print ISSN: 0022-1295
Copyright © 1971 by The Rockefeller University Press
1971
J Gen Physiol (1971) 58 (5): 511–522.
Article history
Received:
February 17 1971
Citation
Merrill Tarr, John Trank; Equivalent Circuit of Frog Atrial Tissue as Determined by Voltage Clamp-Unclamp Experiments . J Gen Physiol 1 November 1971; 58 (5): 511–522. doi: https://doi.org/10.1085/jgp.58.5.511
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.
Sign in via your Institution
Sign in via your InstitutionSuggested Content
Two Inward Currents in Frog Atrial Muscle
J Gen Physiol (November,1971)
Active and passive electrical properties of single bullfrog atrial cells.
J Gen Physiol (July,1981)
Ionic currents in single isolated bullfrog atrial cells.
J Gen Physiol (February,1983)
Email alerts
Advertisement