Analysis of molecular stiffness. (A and B) Histograms (gray bars) and their dual Gaussian fits (green and pink solid curves) of the indicated numbers of stiffness of αLβ2–ICAM-1 molecular complexes measured by the stretch method in Ca2+Mg2+ (A) and Mn2+ (B). The x-axis value with minimum overlap between the two Gaussian distributions (0.5 pN/nm) was used to set a threshold (blue dash line) to differentiate soft (kmol < 0.5 pN/nm) and stiff (kmol > 0.5 pN/nm) αLβ2–ICAM-1 molecular complexes. (C) Relative stiffness (to the value in Mn2+) of the αLβ2–ICAM-1 complex measured using the thermal fluctuation method at zero force in Ca2+Mg2+ or in Mn2+ with or without 1 µM XVA143 (means ± SEM of indicated numbers of measurements). (D) Stiffness (means ± SEM of >50 measurements) of αLβ2–ICAM-1 molecular complexes measured by the stretch method in Mn2+ plus increasing concentration of XVA143 in solution (points directly connected by solid lines). Stiffness of αLβ2–ICAM-1 complexes in Ca2+Mg2+ and of αLβ2–KIM127 complexes in Mn2+, both in the absence of XVA143, are shown as dashed lines (indicated). (E) Histograms of the indicated numbers of αLβ2–ICAM-1 complex stiffness measured before up or down events from the ramp phase using the stretch method. (F) Relative (to the respective values of the putative extended αLβ2–ICAM-1 complex) molecular stiffness before up and down events measured by the stretched method (left), and those before and after up and down events measured by the thermal method (right). Error bars represent SEM of >50 measurements.