TABLE III.

Model-dependent parameters resulting from fit of GV curves

Basic open-channel block 
Scheme 1 Scheme 1a    
    Kbo (µM) 5.90 ± 0.40    
    zc 0.13 ± 0.02 e    
    Kbc (µM)     
    zc     
    SSQ 395.95    
State-independent closed- and open-channel block and variations 
Scheme 2 Scheme 2a Scheme 2a′ Scheme 2b Scheme 2b′ 
    Kbo (µM) 7.42 ± 0.43 6.01 ± 0.30 6.96 ± 0.39 6.36 ± 0.45 
    zc 0.17 ± 0.02 e 0.10 ± 0.02 e 0.15 ± 0.2 e 0.15 ± 0.02 e 
    Kbc (µM) =Kbo 45.79 ± 35.9 =Kbo 21.4 ± 12.2 
    zc =zc 0.81 ± 0.20 e 0.0* 0.0* 
    SSQ 309.199 100.66 486.663 326.09 
Block dependent on movement of one voltage sensor 
Scheme 3 Scheme 3a Scheme 3a′ Scheme 3b Scheme 3b′ 
    Kbo (µM) 6.14 ± 0.26 6.01 ± 0.27 6.02 ± 0.29 6.48 ± 0.29 
    zo 0.13 ± 0.01 e 0.10 ± 0.02 e 0.13 ± 0.02 e 0.13 ± 0.01 e 
    Kbc (µM) =Kbo 8.1 ± 6.7 =Kbo 2.34 ± 0.38 
    zc =zc 0.44 ± 0.23 e 0.0 0.0* 
    SSQ 159.163 93.75 209.18 138.242 
Block scales with movement of each voltage sensor 
Scheme 4  Scheme 4a′  Scheme 4b′ 
    4 Kbo (µM)  19.53 ± 0.9  20.78 ± 0.80 
    zo  0.06 ± 0.02 e  0.08 ± 0.01 e 
    4 Kbc (µM)  7.4 ± 5.2  3.05 ± 0.44 
    zc  0.30 ± 0.21 e  0.0* 
    SSQ  90.3005  106.822 
Closed-channel block scales with movement of each voltage sensor; open channels are blocked identically 
Scheme 5  Scheme 5a′  Scheme 5b′ 
    Kbo (µM)  6.03 ± 0.28  6.38 ± 0.26 
    zo  0.10 ± 0.02 e  0.12 ± 0.01 e 
    4 Kbc (µM)  8.52 ± 6.4  3.21 ± 0.48 
    zc  0.33 ± 0.23 e  0.0* 
    SSQ  95.99  121.019 
Closed channel block depends on movement of two voltage sensors 
Scheme 6  Scheme 6a′  Scheme 6b′ 
    Kbo (µM)  6.04 ± 0.24  5.70 ± 0.23 
    zo  0.10 ± 0.02 e  0.069 ± 0.01 e 
    4 Kbc (µM)  0.02 ± 0.02  .174 ± 0.02 
    zc  0.62 ± 0.23 e  0.0* 
    SSQ  89.91  124.9026 
Basic open-channel block 
Scheme 1 Scheme 1a    
    Kbo (µM) 5.90 ± 0.40    
    zc 0.13 ± 0.02 e    
    Kbc (µM)     
    zc     
    SSQ 395.95    
State-independent closed- and open-channel block and variations 
Scheme 2 Scheme 2a Scheme 2a′ Scheme 2b Scheme 2b′ 
    Kbo (µM) 7.42 ± 0.43 6.01 ± 0.30 6.96 ± 0.39 6.36 ± 0.45 
    zc 0.17 ± 0.02 e 0.10 ± 0.02 e 0.15 ± 0.2 e 0.15 ± 0.02 e 
    Kbc (µM) =Kbo 45.79 ± 35.9 =Kbo 21.4 ± 12.2 
    zc =zc 0.81 ± 0.20 e 0.0* 0.0* 
    SSQ 309.199 100.66 486.663 326.09 
Block dependent on movement of one voltage sensor 
Scheme 3 Scheme 3a Scheme 3a′ Scheme 3b Scheme 3b′ 
    Kbo (µM) 6.14 ± 0.26 6.01 ± 0.27 6.02 ± 0.29 6.48 ± 0.29 
    zo 0.13 ± 0.01 e 0.10 ± 0.02 e 0.13 ± 0.02 e 0.13 ± 0.01 e 
    Kbc (µM) =Kbo 8.1 ± 6.7 =Kbo 2.34 ± 0.38 
    zc =zc 0.44 ± 0.23 e 0.0 0.0* 
    SSQ 159.163 93.75 209.18 138.242 
Block scales with movement of each voltage sensor 
Scheme 4  Scheme 4a′  Scheme 4b′ 
    4 Kbo (µM)  19.53 ± 0.9  20.78 ± 0.80 
    zo  0.06 ± 0.02 e  0.08 ± 0.01 e 
    4 Kbc (µM)  7.4 ± 5.2  3.05 ± 0.44 
    zc  0.30 ± 0.21 e  0.0* 
    SSQ  90.3005  106.822 
Closed-channel block scales with movement of each voltage sensor; open channels are blocked identically 
Scheme 5  Scheme 5a′  Scheme 5b′ 
    Kbo (µM)  6.03 ± 0.28  6.38 ± 0.26 
    zo  0.10 ± 0.02 e  0.12 ± 0.01 e 
    4 Kbc (µM)  8.52 ± 6.4  3.21 ± 0.48 
    zc  0.33 ± 0.23 e  0.0* 
    SSQ  95.99  121.019 
Closed channel block depends on movement of two voltage sensors 
Scheme 6  Scheme 6a′  Scheme 6b′ 
    Kbo (µM)  6.04 ± 0.24  5.70 ± 0.23 
    zo  0.10 ± 0.02 e  0.069 ± 0.01 e 
    4 Kbc (µM)  0.02 ± 0.02  .174 ± 0.02 
    zc  0.62 ± 0.23 e  0.0* 
    SSQ  89.91  124.9026 

or Create an Account

Close Modal
Close Modal