Table I.

Spike and SAF parameters: control versus 100 µM ryanodine

Parameter Control mean ± SEM 100 µM ryanodine mean ± SEM p-value 
Spikes    
    Amplitude (pA) 9.20 ± 2.3 15.90 ± 1.6 *0.026 
    Rise timea (ms) 6.78 ± 0.65 10.83 ± 0.95 *0.002 
    Half-width (ms) 11.79 ± 0.89 15.23 ± 1.5 0.068 
    τb (ms) 11.45 ± 0.87 14.23 ± 1.38 0.099 
    Duration (ms) 62.99 ± 4.86 84.49 ± 7.56 *0.027 
SAFs    
    Amplitude (pA) 1.09 ± 0.03 1.84 ± 0.06 *0.000 
    Duration (ms) 32.68 ± 3.6 33.55 ± 4.3 0.877 
Parameter Control mean ± SEM 100 µM ryanodine mean ± SEM p-value 
Spikes    
    Amplitude (pA) 9.20 ± 2.3 15.90 ± 1.6 *0.026 
    Rise timea (ms) 6.78 ± 0.65 10.83 ± 0.95 *0.002 
    Half-width (ms) 11.79 ± 0.89 15.23 ± 1.5 0.068 
    τb (ms) 11.45 ± 0.87 14.23 ± 1.38 0.099 
    Duration (ms) 62.99 ± 4.86 84.49 ± 7.56 *0.027 
SAFs    
    Amplitude (pA) 1.09 ± 0.03 1.84 ± 0.06 *0.000 
    Duration (ms) 32.68 ± 3.6 33.55 ± 4.3 0.877 

p-values are from two sample Student's t tests.

a

Rise time is 10–90%.

b

τ is 67% decay.