Table 2.
Fit parameters for activation of concatenated channels used in the study in control conditions and at saturating retigabine concentrations
ConstructControl V1/2 (mV)Max shifted V1/2 (mV)Control k (mV)Max shifted k (mV)n
WWWW −44 ± 3 −103 ± 3 9.4 ± 1.1 7.8 ± 0.4 
WWWF −43.8 ± 0.7 −101.0 ± 1.3 6.9 ± 0.1 9.2 ± 0.1 
WWFF −44.1 ± 0.7 −93 ± 1 6.9 ± 0.1 12.0 ± 0.6 
WFFF −43.4 ± 1.2 −91.9 ± 0.7 9.3 ± 0.5 11.1 ± 0.2 
FFFF −42.8 ± 0.9 −46.3 ± 1 8.4 ± 0.9 7.3 ± 0.7 
ConstructControl V1/2 (mV)Max shifted V1/2 (mV)Control k (mV)Max shifted k (mV)n
WWWW −44 ± 3 −103 ± 3 9.4 ± 1.1 7.8 ± 0.4 
WWWF −43.8 ± 0.7 −101.0 ± 1.3 6.9 ± 0.1 9.2 ± 0.1 
WWFF −44.1 ± 0.7 −93 ± 1 6.9 ± 0.1 12.0 ± 0.6 
WFFF −43.4 ± 1.2 −91.9 ± 0.7 9.3 ± 0.5 11.1 ± 0.2 
FFFF −42.8 ± 0.9 −46.3 ± 1 8.4 ± 0.9 7.3 ± 0.7 

Conductance–voltage relationships were fit with the equation G/Gmax = 1/(1 + e−(V-V1/2)/k). Data are mean ± SEM.