Table 9.

Scheme 4 parameters and fitted values from simulated data

Parameter Quantity Units Fit (mean ± SEM) p-value 
ΔqL 0.3a eo 0.305 ± 0.002 (n = 10) 0.063 
ΔGL 350a meV —  
ΔqJ1 0.2b eo —  
ΔGJ1 121c meV —  
ΔqJ2 0.38d eo —  
ΔGJ2 157c meV —  
ΔnK1 1.0 — —  
ΔGK1 79e meV —  
ΔnK2 1.0 — —  
ΔGK2 29e meV —  
ΔWC −53a meV −52.5 ± 0.7 (n = 10) 0.417 
ΔWD −81a meV −78.6 ± 0.7 (n = 10) 0.009 
ΔWC + ΔWE −75a meV −69.6 ± 2.3 (n = 10) 0.044 
ΔWF 20e meV —  
ΔWG −195c meV —  
αL 0.1a kHz —  
αJ 10a kHz —  
αK 10a kHz —  
ΔqT 2.62f eo 2.56 ± 0.03 (n = 10) 0.055 
gL 50 pS —  
Parameter Quantity Units Fit (mean ± SEM) p-value 
ΔqL 0.3a eo 0.305 ± 0.002 (n = 10) 0.063 
ΔGL 350a meV —  
ΔqJ1 0.2b eo —  
ΔGJ1 121c meV —  
ΔqJ2 0.38d eo —  
ΔGJ2 157c meV —  
ΔnK1 1.0 — —  
ΔGK1 79e meV —  
ΔnK2 1.0 — —  
ΔGK2 29e meV —  
ΔWC −53a meV −52.5 ± 0.7 (n = 10) 0.417 
ΔWD −81a meV −78.6 ± 0.7 (n = 10) 0.009 
ΔWC + ΔWE −75a meV −69.6 ± 2.3 (n = 10) 0.044 
ΔWF 20e meV —  
ΔWG −195c meV —  
αL 0.1a kHz —  
αJ 10a kHz —  
αK 10a kHz —  
ΔqT 2.62f eo 2.56 ± 0.03 (n = 10) 0.055 
gL 50 pS —  
a

Parameters adopted from Horrigan and Aldrich (2002).

b

Parameters adopted from Pantazis et al. (2010).

c

Parameters obtained from simultaneous fits to Q-V and G-V curves at [Ca2+] = 10−3 and 70 µM obtained from the HA model.

d

= ΔqJ − ΔqJ1, where ΔqJ = 0.58 eo is adopted from Horrigan and Aldrich (2002).

e

Parameters adopted from Sweet and Cox (2008).

f

ΔqT = ΔqL + 4(ΔqJ1 + ΔqJ2).