Recovery fractional magnitudes of recovery from SI
| Channel variant (measured parameter) | Pulse | AF | AI | AS | C | n |
| s | ||||||
| WT (I) | 5 | 0.10 ± 0.02 (0.89) | 0.00 ± 0.00 (0.05) | 0.01 ± 0.01 (0.06) | 0.89 ± 0.03 | 4 |
| WT (I) | 40 | 0.13 ± 0.02 (0.32)a | 0.15 ± 0.04 (0.37)a | 0.12 ± 0.01 (0.31)a | 0.60 ± 0.03 | 4 |
| WT (I) | 160 | 0.07 ± 0.03 (0.10)ab | 0.35 ± 0.02 (0.50)a | 0.28 ± 0.02 (0.41)a | 0.30 ± 0.05 | 4 |
| WT (Q) | 5 | 0.10 ± 0.02 (0.73) | 0.03 ± 0.02 (0.25) | 0.00 ± 0.00 (0.02) | 0.86 ± 0.03 | 5 |
| WT (Q) | 40 | 0.12 ± 0.02 (0.48)a | 0.12 ± 0.02 (0.51)a | 0.03 ± 0.03 (0.01) | 0.76 ± 0.03 | 5 |
| WT (Q) | 160 | 0.15 ± 0.03 (0.39)a | 0.18 ± 0.07 (0.48)a | 0.05 ± 0.01 (0.13)b | 0.62 ± 0.08 | 5 |
| DI (F) | 5 | 0.17 ± 0.04 (0.98) | 0.00 ± 0.00 (0.02) | 0.00 ± 0.00 (0.00) | 0.83 ± 0.04 | 7 |
| DI (F) | 40 | 0.22 ± 0.05 (0.53)a | 0.19 ± 0.04 (0.46)a | 0.00 ± 0.00 (0.01) | 0.59 ± 0.04 | 7 |
| DI (F) | 160 | 0.13 ± 0.03 (0.35)a | 0.18 ± 0.03 (0.46)a | 0.08 ± 0.03 (0.20)ab | 0.61 ± 0.04 | 7 |
| DII (F) | 5 | 0.20 ± 0.08 (0.94) | 0.01 ± 0.01 (0.06) | 0.00 ± 0.00 (0.00) | 0.79 ± 0.07 | 3 |
| DII (F) | 40 | 0.12 ± 0.10 (0.36) | 0.21 ± 0.02 (0.61) | 0.01 ± 0.01 (0.03) | 0.66 ± 0.09 | 3 |
| DII (F) | 160 | 0.13 ± 0.11 (0.28) | 0.22 ± 0.07 (0.49) | 0.11 ± 0.03 (0.23)ab | 0.54 ± 0.06 | 3 |
| DIII (F) | 5 | 0.34 ± 0.08 (0.89) | 0.04 ± 0.02 (0.09) | 0.01 ± 0.01 (0.02) | 0.61 ± 0.06 | 6 |
| DIII (F) | 40 | 0.16 ± 0.08 (0.32)a | 0.18 ± 0.05 (0.36) | 0.17 ± 0.03 (0.32)a | 0.48 ± 0.06 | 6 |
| DIII (F) | 160 | 0.04 ± 0.04 (0.07)a | 0.23 ± 0.01 (0.38)a | 0.32 ± 0.03 (0.55)ab | 0.41 ± 0.02 | 6 |
| DIV (F) | 5 | 0.08 ± 0.05 (0.72) | 0.03 ± 0.01 (0.28) | 0.00 ± 0.00 (0.00) | 0.89 ± 0.05 | 7 |
| DIV (F) | 40 | 0.03 ± 0.02 (0.12)a | 0.14 ± 0.02 (0.59) | 0.07 ± 0.03 (0.29)a | 0.76 ± 0.04 | 7 |
| DIV (F) | 160 | 0.07 ± 0.03 (0.19)a | 0.11 ± 0.02 (0.31)b | 0.18 ± 0.03 (0.50)ab | 0.65 ± 0.05 | 7 |
| Channel variant (measured parameter) | Pulse | AF | AI | AS | C | n |
| s | ||||||
| WT (I) | 5 | 0.10 ± 0.02 (0.89) | 0.00 ± 0.00 (0.05) | 0.01 ± 0.01 (0.06) | 0.89 ± 0.03 | 4 |
| WT (I) | 40 | 0.13 ± 0.02 (0.32)a | 0.15 ± 0.04 (0.37)a | 0.12 ± 0.01 (0.31)a | 0.60 ± 0.03 | 4 |
| WT (I) | 160 | 0.07 ± 0.03 (0.10)ab | 0.35 ± 0.02 (0.50)a | 0.28 ± 0.02 (0.41)a | 0.30 ± 0.05 | 4 |
| WT (Q) | 5 | 0.10 ± 0.02 (0.73) | 0.03 ± 0.02 (0.25) | 0.00 ± 0.00 (0.02) | 0.86 ± 0.03 | 5 |
| WT (Q) | 40 | 0.12 ± 0.02 (0.48)a | 0.12 ± 0.02 (0.51)a | 0.03 ± 0.03 (0.01) | 0.76 ± 0.03 | 5 |
| WT (Q) | 160 | 0.15 ± 0.03 (0.39)a | 0.18 ± 0.07 (0.48)a | 0.05 ± 0.01 (0.13)b | 0.62 ± 0.08 | 5 |
| DI (F) | 5 | 0.17 ± 0.04 (0.98) | 0.00 ± 0.00 (0.02) | 0.00 ± 0.00 (0.00) | 0.83 ± 0.04 | 7 |
| DI (F) | 40 | 0.22 ± 0.05 (0.53)a | 0.19 ± 0.04 (0.46)a | 0.00 ± 0.00 (0.01) | 0.59 ± 0.04 | 7 |
| DI (F) | 160 | 0.13 ± 0.03 (0.35)a | 0.18 ± 0.03 (0.46)a | 0.08 ± 0.03 (0.20)ab | 0.61 ± 0.04 | 7 |
| DII (F) | 5 | 0.20 ± 0.08 (0.94) | 0.01 ± 0.01 (0.06) | 0.00 ± 0.00 (0.00) | 0.79 ± 0.07 | 3 |
| DII (F) | 40 | 0.12 ± 0.10 (0.36) | 0.21 ± 0.02 (0.61) | 0.01 ± 0.01 (0.03) | 0.66 ± 0.09 | 3 |
| DII (F) | 160 | 0.13 ± 0.11 (0.28) | 0.22 ± 0.07 (0.49) | 0.11 ± 0.03 (0.23)ab | 0.54 ± 0.06 | 3 |
| DIII (F) | 5 | 0.34 ± 0.08 (0.89) | 0.04 ± 0.02 (0.09) | 0.01 ± 0.01 (0.02) | 0.61 ± 0.06 | 6 |
| DIII (F) | 40 | 0.16 ± 0.08 (0.32)a | 0.18 ± 0.05 (0.36) | 0.17 ± 0.03 (0.32)a | 0.48 ± 0.06 | 6 |
| DIII (F) | 160 | 0.04 ± 0.04 (0.07)a | 0.23 ± 0.01 (0.38)a | 0.32 ± 0.03 (0.55)ab | 0.41 ± 0.02 | 6 |
| DIV (F) | 5 | 0.08 ± 0.05 (0.72) | 0.03 ± 0.01 (0.28) | 0.00 ± 0.00 (0.00) | 0.89 ± 0.05 | 7 |
| DIV (F) | 40 | 0.03 ± 0.02 (0.12)a | 0.14 ± 0.02 (0.59) | 0.07 ± 0.03 (0.29)a | 0.76 ± 0.04 | 7 |
| DIV (F) | 160 | 0.07 ± 0.03 (0.19)a | 0.11 ± 0.02 (0.31)b | 0.18 ± 0.03 (0.50)ab | 0.65 ± 0.05 | 7 |
Similar to SI onset, recovery from SI can be fit with three time constants, τF = 0.6 ± 0.3 s, τI = 4.5 ± 1.1 s, and τS = 43.1 ± 4.8 s, which were found by fitting the recovery of the wild-type ionic current after a 160-s depolarizing pulse to +45. The fractional magnitudes below are for pulses to +45 mV lasting 5, 40, and 160 s. The absolute values correlate to the fraction inactivated during onset, which are described in Tables 1 and 2. To compute significance differences in time constants between durations, magnitudes were normalized to the fraction inactivated (shown in parentheses). For example, after the 5-s pulse, the fraction of current inactivated with τF was 0.91. p-values were computed to compare fraction inactivated with a given τ. I, the ionic current recovery in Fig. 6 A; Q, the gating current recovery in Fig. 6 B; DI, DII, DIII, and DIV, the fluorescence recoveries in Fig. 7 B. Channel variant abbreviations as in Table 1.
Significantly different (P < 0.05) from the 5-s pulse.
Significantly different from 40 s (160 pulses).