Table 3.

Recovery fractional magnitudes of recovery from SI

Channel variant (measured parameter) Pulse AF AI AS n 
 s      
WT (I) 0.10 ± 0.02 (0.89) 0.00 ± 0.00 (0.05) 0.01 ± 0.01 (0.06) 0.89 ± 0.03 
WT (I) 40 0.13 ± 0.02 (0.32)a 0.15 ± 0.04 (0.37)a 0.12 ± 0.01 (0.31)a 0.60 ± 0.03 
WT (I) 160 0.07 ± 0.03 (0.10)ab 0.35 ± 0.02 (0.50)a 0.28 ± 0.02 (0.41)a 0.30 ± 0.05 
WT (Q) 0.10 ± 0.02 (0.73) 0.03 ± 0.02 (0.25) 0.00 ± 0.00 (0.02) 0.86 ± 0.03 
WT (Q) 40 0.12 ± 0.02 (0.48)a 0.12 ± 0.02 (0.51)a 0.03 ± 0.03 (0.01) 0.76 ± 0.03 
WT (Q) 160 0.15 ± 0.03 (0.39)a 0.18 ± 0.07 (0.48)a 0.05 ± 0.01 (0.13)b 0.62 ± 0.08 
DI (F) 0.17 ± 0.04 (0.98) 0.00 ± 0.00 (0.02) 0.00 ± 0.00 (0.00) 0.83 ± 0.04 
DI (F) 40 0.22 ± 0.05 (0.53)a 0.19 ± 0.04 (0.46)a 0.00 ± 0.00 (0.01) 0.59 ± 0.04 
DI (F) 160 0.13 ± 0.03 (0.35)a 0.18 ± 0.03 (0.46)a 0.08 ± 0.03 (0.20)ab 0.61 ± 0.04 
DII (F) 0.20 ± 0.08 (0.94) 0.01 ± 0.01 (0.06) 0.00 ± 0.00 (0.00) 0.79 ± 0.07 
DII (F) 40 0.12 ± 0.10 (0.36) 0.21 ± 0.02 (0.61) 0.01 ± 0.01 (0.03) 0.66 ± 0.09 
DII (F) 160 0.13 ± 0.11 (0.28) 0.22 ± 0.07 (0.49) 0.11 ± 0.03 (0.23)ab 0.54 ± 0.06 
DIII (F) 0.34 ± 0.08 (0.89) 0.04 ± 0.02 (0.09) 0.01 ± 0.01 (0.02) 0.61 ± 0.06 
DIII (F) 40 0.16 ± 0.08 (0.32)a 0.18 ± 0.05 (0.36) 0.17 ± 0.03 (0.32)a 0.48 ± 0.06 
DIII (F) 160 0.04 ± 0.04 (0.07)a 0.23 ± 0.01 (0.38)a 0.32 ± 0.03 (0.55)ab 0.41 ± 0.02 
DIV (F) 0.08 ± 0.05 (0.72) 0.03 ± 0.01 (0.28) 0.00 ± 0.00 (0.00) 0.89 ± 0.05 
DIV (F) 40 0.03 ± 0.02 (0.12)a 0.14 ± 0.02 (0.59) 0.07 ± 0.03 (0.29)a 0.76 ± 0.04 
DIV (F) 160 0.07 ± 0.03 (0.19)a 0.11 ± 0.02 (0.31)b 0.18 ± 0.03 (0.50)ab 0.65 ± 0.05 
Channel variant (measured parameter) Pulse AF AI AS n 
 s      
WT (I) 0.10 ± 0.02 (0.89) 0.00 ± 0.00 (0.05) 0.01 ± 0.01 (0.06) 0.89 ± 0.03 
WT (I) 40 0.13 ± 0.02 (0.32)a 0.15 ± 0.04 (0.37)a 0.12 ± 0.01 (0.31)a 0.60 ± 0.03 
WT (I) 160 0.07 ± 0.03 (0.10)ab 0.35 ± 0.02 (0.50)a 0.28 ± 0.02 (0.41)a 0.30 ± 0.05 
WT (Q) 0.10 ± 0.02 (0.73) 0.03 ± 0.02 (0.25) 0.00 ± 0.00 (0.02) 0.86 ± 0.03 
WT (Q) 40 0.12 ± 0.02 (0.48)a 0.12 ± 0.02 (0.51)a 0.03 ± 0.03 (0.01) 0.76 ± 0.03 
WT (Q) 160 0.15 ± 0.03 (0.39)a 0.18 ± 0.07 (0.48)a 0.05 ± 0.01 (0.13)b 0.62 ± 0.08 
DI (F) 0.17 ± 0.04 (0.98) 0.00 ± 0.00 (0.02) 0.00 ± 0.00 (0.00) 0.83 ± 0.04 
DI (F) 40 0.22 ± 0.05 (0.53)a 0.19 ± 0.04 (0.46)a 0.00 ± 0.00 (0.01) 0.59 ± 0.04 
DI (F) 160 0.13 ± 0.03 (0.35)a 0.18 ± 0.03 (0.46)a 0.08 ± 0.03 (0.20)ab 0.61 ± 0.04 
DII (F) 0.20 ± 0.08 (0.94) 0.01 ± 0.01 (0.06) 0.00 ± 0.00 (0.00) 0.79 ± 0.07 
DII (F) 40 0.12 ± 0.10 (0.36) 0.21 ± 0.02 (0.61) 0.01 ± 0.01 (0.03) 0.66 ± 0.09 
DII (F) 160 0.13 ± 0.11 (0.28) 0.22 ± 0.07 (0.49) 0.11 ± 0.03 (0.23)ab 0.54 ± 0.06 
DIII (F) 0.34 ± 0.08 (0.89) 0.04 ± 0.02 (0.09) 0.01 ± 0.01 (0.02) 0.61 ± 0.06 
DIII (F) 40 0.16 ± 0.08 (0.32)a 0.18 ± 0.05 (0.36) 0.17 ± 0.03 (0.32)a 0.48 ± 0.06 
DIII (F) 160 0.04 ± 0.04 (0.07)a 0.23 ± 0.01 (0.38)a 0.32 ± 0.03 (0.55)ab 0.41 ± 0.02 
DIV (F) 0.08 ± 0.05 (0.72) 0.03 ± 0.01 (0.28) 0.00 ± 0.00 (0.00) 0.89 ± 0.05 
DIV (F) 40 0.03 ± 0.02 (0.12)a 0.14 ± 0.02 (0.59) 0.07 ± 0.03 (0.29)a 0.76 ± 0.04 
DIV (F) 160 0.07 ± 0.03 (0.19)a 0.11 ± 0.02 (0.31)b 0.18 ± 0.03 (0.50)ab 0.65 ± 0.05 

Similar to SI onset, recovery from SI can be fit with three time constants, τF = 0.6 ± 0.3 s, τI = 4.5 ± 1.1 s, and τS = 43.1 ± 4.8 s, which were found by fitting the recovery of the wild-type ionic current after a 160-s depolarizing pulse to +45. The fractional magnitudes below are for pulses to +45 mV lasting 5, 40, and 160 s. The absolute values correlate to the fraction inactivated during onset, which are described in Tables 1 and 2. To compute significance differences in time constants between durations, magnitudes were normalized to the fraction inactivated (shown in parentheses). For example, after the 5-s pulse, the fraction of current inactivated with τF was 0.91. p-values were computed to compare fraction inactivated with a given τ. I, the ionic current recovery in Fig. 6 A; Q, the gating current recovery in Fig. 6 B; DI, DII, DIII, and DIV, the fluorescence recoveries in Fig. 7 B. Channel variant abbreviations as in Table 1.

a

Significantly different (P < 0.05) from the 5-s pulse.

b

Significantly different from 40 s (160 pulses).