Table 2.

Lobule geometries and exponential fitting parameters from Rho-PAGFP mFRAPa experiments1

Cell Lobule area Lobule width Conduit width Outer segment diameter tau 1 tau 2 
 µm2 µm µm µm      
4.702 1.72 1.00 7.66 0.87 0.19 0.035 0.247 21.01 
5.493 1.93 0.14 8.69 0.82 0.21 0.003 2.703 526.32 
3.671 1.55 1.07 6.51 0.72 0.19 0.035 0.953 57.14 
3.923 1.19 2.10 6.62 0.71 0.14 0.029 0.641 40.00 
2.829 1.48 0.90 4.98 0.78 0.16 0.052 0.292 28.57 
4.403 1.37 0.88 7.51 0.85 0.12 0.020 0.358 70.62 
2.101 1.75 0.80 6.89 0.79 0.20 0.027 1.064 80.65 
3.654 1.54 0.33 7.18 0.75 0.12 0.070 0.785 209.64 
4.212 1.47 1.54 6.63 0.76 0.20 0.066 1.188 52.08 
10 4.783 0.98 0.14 7.09 0.64 0.29 0.030 2.392 354.74 
11 1.463 1.58 0.54 6.50 0.85 0.13 0.055 0.368 78.74 
mean 3.75 1.505 0.858 6.93 0.776 0.178 0.038 1.00 138.14 
SEM 0.36 0.079 0.178 0.28 0.022 0.015 0.006 0.25 48.94 
Cell Lobule area Lobule width Conduit width Outer segment diameter tau 1 tau 2 
 µm2 µm µm µm      
4.702 1.72 1.00 7.66 0.87 0.19 0.035 0.247 21.01 
5.493 1.93 0.14 8.69 0.82 0.21 0.003 2.703 526.32 
3.671 1.55 1.07 6.51 0.72 0.19 0.035 0.953 57.14 
3.923 1.19 2.10 6.62 0.71 0.14 0.029 0.641 40.00 
2.829 1.48 0.90 4.98 0.78 0.16 0.052 0.292 28.57 
4.403 1.37 0.88 7.51 0.85 0.12 0.020 0.358 70.62 
2.101 1.75 0.80 6.89 0.79 0.20 0.027 1.064 80.65 
3.654 1.54 0.33 7.18 0.75 0.12 0.070 0.785 209.64 
4.212 1.47 1.54 6.63 0.76 0.20 0.066 1.188 52.08 
10 4.783 0.98 0.14 7.09 0.64 0.29 0.030 2.392 354.74 
11 1.463 1.58 0.54 6.50 0.85 0.13 0.055 0.368 78.74 
mean 3.75 1.505 0.858 6.93 0.776 0.178 0.038 1.00 138.14 
SEM 0.36 0.079 0.178 0.28 0.022 0.015 0.006 0.25 48.94 

mFRAPa recoveries were fitted with the following equation: F(t)F0=aexp(ttau1)+bexp(ttau2)+c, where F is the fluorescence at the photoactivation site, and F0 is the fluorescence at that site immediately after photoactivation.