| Condition . | Spindle . | Attach . | Tension . | SAC . | Dam1C/DASH rings . | kMT . | ||
|---|---|---|---|---|---|---|---|---|
| . | . | . | . | . | Complete . | Partial . | n . | nm . |
| Metaphase | Intact | + | + | OFF | 39% | 61% | 46 | 50–200+ |
| Nocodazole treatment | MT stubs | + | − | ON | 86% | 14% | 7 | 20–50 |
| Absent | − | − | ON | 0% | 100% | 37 | n/a | |
| Metaphase, Scc1 cleaved; Scc1-TEV268 | Distorted | + | − | ON | 39% | 61% | 33 | 50–200+ |
| Condition . | Spindle . | Attach . | Tension . | SAC . | Dam1C/DASH rings . | kMT . | ||
|---|---|---|---|---|---|---|---|---|
| . | . | . | . | . | Complete . | Partial . | n . | nm . |
| Metaphase | Intact | + | + | OFF | 39% | 61% | 46 | 50–200+ |
| Nocodazole treatment | MT stubs | + | − | ON | 86% | 14% | 7 | 20–50 |
| Absent | − | − | ON | 0% | 100% | 37 | n/a | |
| Metaphase, Scc1 cleaved; Scc1-TEV268 | Distorted | + | − | ON | 39% | 61% | 33 | 50–200+ |
n/a: kMT length unknown because they were not within the same cryosection as the kinetochore. Note that out of 86 attached Dam1C/DASH rings, kMT-tip-to-Dam1C/DASH distances could be measured for only 56 of them. Also, note that, due to the flexibility of the rings and the low contrast of cryotomograms, not every ring could be used to make both diameter and circumference/curvature measurements.