Skip to Main Content
TABLE III

Results of Applied Pressure MD Simulations for H2O

Applied pressure
Time
No. of H2O
 permeations
Flux
pf × 1014
MPa ns  H2O/ns/pore cm3/s/pore 
25 21 0.65 10.0 ± 0.56 
50 26.8 107 1.0  
100 21.9 171 1.9  
200 22 455 5.2  
Applied pressure
Time
No. of H2O
 permeations
Flux
pf × 1014
MPa ns  H2O/ns/pore cm3/s/pore 
25 21 0.65 10.0 ± 0.56 
50 26.8 107 1.0  
100 21.9 171 1.9  
200 22 455 5.2  