Page 789

Due to a typesetting error, the symbols for rate constants in Table were printed incorrectly. The corrected table appears below:

Table 2

Rate Constants of RyR Models Used for Simulation of Channel Activity

Rate constantModel 1CaModel 2CaModel 3CaModel 4CaModel 5CaUnit
kon 1.0 × 103 9.2 × 102 8.2 × 102 7.1 × 102 7.1 × 102 μM−1· s−1 
koff 1.0 × 105 1.4 × 104 5.5 × 103 3.0 × 103 2.0 × 103 s−1 
kCn O1   1.0 × 104   s−1 
kCn O2   1.0 × 100   s−1 
kO1 Cn   5.0 × 102   s−1 
kO2 Cn   5.0 × 10−1   s−1 
kO1 Cn+1   2.0 × 100   s−1 
kCn+1 O1   6.7 × 10−1   s−1 
kO2 Cn+1   3.0 × 103   s−1 
kCn+1 O2   1.0 × 102   s−1 
kCn+1 I   5.0 × 10−1   s−1 
kI Cn+1   1.5 × 100   s−1 
Rate constantModel 1CaModel 2CaModel 3CaModel 4CaModel 5CaUnit
kon 1.0 × 103 9.2 × 102 8.2 × 102 7.1 × 102 7.1 × 102 μM−1· s−1 
koff 1.0 × 105 1.4 × 104 5.5 × 103 3.0 × 103 2.0 × 103 s−1 
kCn O1   1.0 × 104   s−1 
kCn O2   1.0 × 100   s−1 
kO1 Cn   5.0 × 102   s−1 
kO2 Cn   5.0 × 10−1   s−1 
kO1 Cn+1   2.0 × 100   s−1 
kCn+1 O1   6.7 × 10−1   s−1 
kO2 Cn+1   3.0 × 103   s−1 
kCn+1 O2   1.0 × 102   s−1 
kCn+1 I   5.0 × 10−1   s−1 
kI Cn+1   1.5 × 100   s−1