A technique for the examination of specimens at low electron beam intensity has been presented. Sections micrographed with this technique showed numerous knife scratches and frequently contained bands running parallel to the knife edge. Banding with an average spacing of 0.2 µ appeared to result from periodic distortion produced by impact of the knife. At the beam intensities customarily employed, differential sublimation and probably flow of the methacrylate resulted in obliteration of the bands and all but the deepest knife scratches. In addition, changes in the size, shape, and orientation of certain structures were noted. Artifacts resulting from incineration or sublimation of tissue components fixed in formalin were illustrated, and the suggestion was made that such instability to the electron beam accounted in part for the differences observed in osmium- and formalin-fixed tissues. The deformation revealed in serial sections was discussed, and it was pointed out that shortening in the axis perpendicular to the knife edge was associated with elongation in the axis parallel to the cutting edge, the elongation usually occurring locally without change in the width of the section. It was noted that the material causing contamination of the surface of sections during examination exhibited no structure but caused progressive loss of contrast.
Skip Nav Destination
Article navigation
25 July 1956
Content prior to 1962 was published under the journal name
The Journal of Biophysical and Biochemical Cytology
Article|
July 25 1956
SOME EFFECTS OF THE MICROTOME KNIFE AND ELECTRON BEAM ON METHACRYLATE-EMBEDDED THIN SECTIONS
Councilman Morgan,
Councilman Morgan
From the Departments of Microbiology and Medicine, College of Physicians and Surgeons, Columbia University, New York
Search for other works by this author on:
Dan H. Moore,
Dan H. Moore
From the Departments of Microbiology and Medicine, College of Physicians and Surgeons, Columbia University, New York
Search for other works by this author on:
Harry M. Rose
Harry M. Rose
From the Departments of Microbiology and Medicine, College of Physicians and Surgeons, Columbia University, New York
Search for other works by this author on:
Councilman Morgan
From the Departments of Microbiology and Medicine, College of Physicians and Surgeons, Columbia University, New York
Dan H. Moore
From the Departments of Microbiology and Medicine, College of Physicians and Surgeons, Columbia University, New York
Harry M. Rose
From the Departments of Microbiology and Medicine, College of Physicians and Surgeons, Columbia University, New York
Copyright, 1956, by The Rockefeller Institute for Medical Research
1956
J Biophys and Biochem Cytol (1956) 2 (4): 21–28.
Citation
Councilman Morgan, Dan H. Moore, Harry M. Rose; SOME EFFECTS OF THE MICROTOME KNIFE AND ELECTRON BEAM ON METHACRYLATE-EMBEDDED THIN SECTIONS . J Biophys and Biochem Cytol 25 July 1956; 2 (4): 21–28. doi: https://doi.org/10.1083/jcb.2.4.21
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.
Sign in via your Institution
Sign in via your InstitutionEmail alerts
Advertisement
Advertisement