Adhesion and subsequent aggregation between neutrophils and platelets is dependent upon the initial binding of P-selectin on activated platelets to P-selectin glycoprotein ligand 1 (PSGL-1) on the microvilli of neutrophils. High speed, high resolution videomicroscopy of flowing neutrophils interacting with spread platelets demonstrated that thin membrane tethers were pulled from neutrophils in 32 ± 4% of the interactions. After capture by spread platelets, neutrophil membrane tethers (length of 5.9 ± 4.1 μm, n = 63) were pulled at an average rate of 6–40 μm/s as the wall shear rate was increased from 100–250 s−1. The average tether lifetime decreased significantly (P < 0.001) from 630 to 133 ms as the shear rate was increased from 100 s−1 (Fbond = 86 pN) to 250 s−1 (Fbond = 172 pN), which is consistent with P-selectin/PSGL-1 bond dynamics under stress. Tether formation was blocked by antibodies against P-selectin or PSGL-1, but not by anti-CD18 antibodies. During neutrophil rolling on P-selectin at 150 s−1, thin membrane tethers were also pulled from the neutrophils. The characteristic jerking motion of the neutrophil coexisted with tether growth (8.9 ± 8.8 μm long), whereas tether breakage (average lifetime of 3.79 ± 3.32 s) caused an acute jump in the rolling velocity, proving multiple bonding in the cell surface and the tether surface contact area. Extremely long membrane tethers (>40 μm) were sometimes pulled, which detached in a flow-dependent mechanism of microparticle formation. Membrane tethers were also formed when neutrophils were perfused over platelet monolayers. These results are the first visualization of the often hypothesized tethers that shield the P-selectin/PSGL-1 bond from force loading to regulate neutrophil rolling during inflammation and thrombosis.
Skip Nav Destination
Article navigation
1 May 2000
Article|
May 01 2000
Direct Observation of Membrane Tethers Formed during Neutrophil Attachment to Platelets or P-Selectin under Physiological Flow
David W. Schmidtke,
David W. Schmidtke
aInstitute for Medicine and Engineering, Department of Chemical Engineering, University of Pennsylvania, Philadelphia, Pennsylvania 19104
Search for other works by this author on:
Scott L. Diamond
Scott L. Diamond
aInstitute for Medicine and Engineering, Department of Chemical Engineering, University of Pennsylvania, Philadelphia, Pennsylvania 19104
Search for other works by this author on:
David W. Schmidtke
aInstitute for Medicine and Engineering, Department of Chemical Engineering, University of Pennsylvania, Philadelphia, Pennsylvania 19104
Scott L. Diamond
aInstitute for Medicine and Engineering, Department of Chemical Engineering, University of Pennsylvania, Philadelphia, Pennsylvania 19104
Abbreviations used in this paper: DIC, differential interference microscopy; PSGL-1, P-selectin glycoprotein ligand 1.
Received:
June 26 1999
Revision Requested:
March 07 2000
Accepted:
March 16 2000
Online ISSN: 1540-8140
Print ISSN: 0021-9525
© 2000 The Rockefeller University Press
2000
The Rockefeller University Press
J Cell Biol (2000) 149 (3): 719–730.
Article history
Received:
June 26 1999
Revision Requested:
March 07 2000
Accepted:
March 16 2000
Citation
David W. Schmidtke, Scott L. Diamond; Direct Observation of Membrane Tethers Formed during Neutrophil Attachment to Platelets or P-Selectin under Physiological Flow. J Cell Biol 1 May 2000; 149 (3): 719–730. doi: https://doi.org/10.1083/jcb.149.3.719
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.
Sign in via your Institution
Sign in via your InstitutionSuggested Content
Email alerts
Advertisement
Advertisement